specialized in the motorized curtain manufacturing

Curtain  Motor, Tubular Motor and Curtain Accessories

24-hour service hotline:

86-20-82696698

Nameplate analysis
Product manuals
Operation video
Common problems and solutions
Download zone
Safety certification
ABUIABACGAAgiunqpwYohMX9lQUw0AM4rgU

KA60A: Company General Model

AC220V: Motor working voltage

50HZ: Motor operating voltage frequency

90W (Max Input): Maximum power during motor operation

1.2N. m: Motor certified torque

112r/min: motor speed

IP41: Dust and waterproof grade

210202: Production date

M0553: Motor program

C25: Motor program version

0032: Production serial number


KR09 Remote Control Manual.jpg
550.25KBDownload
86.A093 KA60-Q 使用说明书(英文).pdf
1.0MBDownload
86.A069.2  KA80 manuals neutral.pdf
1.45MBDownload
Quick Guide of Using Amazon Echo to Control Smart Devices_Tuya Smart_Docs Center.pdf
3.89MBDownload
Quick Guide of Using Google Home to Control Smart Devices_Tuya Smart_Docs Center.pdf
2.38MBDownload
86.A058. 04  KT35-E 使用说明书(斜齿电机中性).pdf
1.02MBDownload
86.0051 KT25E-AN-DN-DBN 使用说明书 (中文).pdf
718.44KBDownload
Prev 1 Next
KECO 35 Tubular Motor Remote Control
KA80 Curtain track installing
KECO 35 Tuya Tubular Motor Internet connection
KECO 35 Tuya Tubular Motor Distribution Network Settings
KECO curtain motor KA80A reversing operation
KECO Shutter motor KA80A reversing operation

ault phenomenon

Fault cause

Resolvent

Press the up button on the controller to move the rolled object down

Internal wiring error in the controller

Just adjust the black and brown positions of the motor lead wires

Connect the power, the motor can only run in one direction

The travel switch in the motor is not open

Rotate the crown 1-2 turns in the opposite direction of its current operation

After the motor is installed and powered on, the motor does not rotate or starts slowly

1. The power supply does not match the rated voltage of the motor

2. Overload

3. Improper installation causing parts to get stuck in the motor

4. Both travel switches in the motor are not open

1. Replace the motor that matches the power supply voltage

2. Replace the motor that matches the load

3. Check if all parts of the accessories are installed correctly

4. Rotate the crown 1-2 turns in any direction

Sudden stop of motor during operation

1. The motor has entered an overheat protection state

2. Power outage

3. Enter the set endpoint

1.After waiting for about 20 minutes for the motor to cool down, it will automatically return to normal working state

2. Call can be restored

3. Depending on the situation, decide whether to adjust the travel knob

Abnormal sound during operation

The transmission pipe is too long, causing the brackets at both ends to be too tight

If the tail plug is movable, cut the outer tube appropriately short

86.A069.2  KA80 manuals neutral.pdf
1.45MBDownload
KR09 Remote Control Manual.jpg
550.25KBDownload
KECO catalogue 2023 -2.pdf
17.44MBDownload
86.A069  KA80 使用说明书.pdf
180.37KBDownload
Prev 1 Next
KA60-CE-TEST-A
KA60-CE-TEST-A
KE45 certificate
KE45 certificate
KR06B-5 CE
KR06B-5 CE
CE[KC86]
CE[KC86]
CE LVD of KA75 KA66 AND KA68
CE LVD of KA75 KA66 AND KA68
KF55-CE
KF55-CE
KA80-82 CE-LVD
KA80-82 CE-LVD
KA80-82 CE-EMC
KA80-82 CE-EMC
KT25 CE
KT25 CE
KT51 CE
KT51 CE
Prev 1 Next
  KECO  products  are  compliant  with  and  approved  by  many  certificates including CE,FCC and CCC.
24-hour service hotline:
86-20-82696698
About us
Name:
Phone:
Content:
Submit